Factory Outlets Techfine OEM Uninterrupted Power Supply 2u 3u Rack Mountable Online UPS 1kVA 2kVA 10kVA WiFi Router UPS Pure Sine Wave
We’re committed to furnishing easy,time-saving and money-saving one-stop purchasing support of consumer for Factory Outlets Techfine OEM Uninterrupted Power Supply 2u 3u Rack Mountable Online UPS 1kVA 2kVA 10kVA WiFi Router UPS Pure Sine Wave, We sincerely welcome all guests to arrange company relationships with us about the basis of mutual positive aspects. You should contact us now. You can get our skilled reply inside of 8 several hours.
We’re committed to furnishing easy,time-saving and money-saving one-stop purchasing support of consumer forChina Online UPS and UPS, Should really any of those items be of curiosity for you, you should allow us to know. We’ll be satisfied to give you a quotation on receipt of one’s thorough specs. We now have our personal experienced R&D enginners to meet any of one’s requriements, We appear forward to receiving your enquires soon’and hope to have the opportunity to work together with you in the future. Welcome to check out our company.
Description
Brand: Banatton
Place of origin: China
Type: online UPS
Model Number: BNT900 1~10KVA
Display: LED
Phase: Single Phase
Waveform: pure sine wave
Transfer time: 0ms
Capacity: 1KVA 2KVA 3KVA 6KVA 10KVA
Protection: short-circuit, over voltages, reverse connection protection
OEM/ODM: Yes
Supply Ability: 10000 Piece/Pieces per Month
Packaging: Carton box package or as you requested
Features


We can apply the following adapters

Our Services
1. OEM&ODM services acceptable.
2. Lots of cooperated agent for shipping by sea or by air.
3. 1year warranty, if it is quality problem, we will provide the parts for free.
Applications

IT infrastructure: small server and workstation, router and switch, monitoring equipment; Automation system: ATM, TVM, SCADA, Railway and Metro signal system; Office and Business Equipment: PC, Printer, Scanner, POS, Telephones and Fax.
Packaging

We’re committed to furnishing easy,time-saving and money-saving one-stop purchasing support of consumer for Factory Outlets Techfine OEM Uninterrupted Power Supply 2u 3u Rack Mountable Online UPS 1kVA 2kVA 10kVA WiFi Router UPS Pure Sine Wave, We sincerely welcome all guests to arrange company relationships with us about the basis of mutual positive aspects. You should contact us now. You can get our skilled reply inside of 8 several hours.
Factory OutletsChina Online UPS and UPS, Should really any of those items be of curiosity for you, you should allow us to know. We’ll be satisfied to give you a quotation on receipt of one’s thorough specs. We now have our personal experienced R&D enginners to meet any of one’s requriements, We appear forward to receiving your enquires soon’and hope to have the opportunity to work together with you in the future. Welcome to check out our company.
| Technical Parameters | ||||||
| MODEL | BNT901S | BNT901H | BNT902S | BNT902H | BNT903S | BNT903H |
| Capacity | 1KVA/800W | 2KVA/1.6KW | 3KVA/2.4KW | |||
| INPUT | ||||||
| Input system | Single phase(L/N+PE) | |||||
| Norminal voltage | HV:208/220/230/240/280Vac; LV:100/110/120/127Vac | |||||
| Voltage range | HV: 90 ~ 300Vac± 5Vac; LV: 60~145Vac± 3Vac | |||||
| Frequency | 40~70Hzc±0.5Hz | |||||
| Power factor | ≥ 0.99 @100% load | |||||
| Bypass voltage range | HV:115~285Vac×(1±3%); LV:80~140Vac×(1±3%) | |||||
| OUTPUT | ||||||
| Output system | Single phase(L/N+PE) | |||||
| Output Voltage | HV:208/220/230/240Vac; LV:100/110/120/127Vac | |||||
| Voltage regulation | ± 1% | |||||
| Frequency | 50/60Hz±4Hz (sync mode); 50 or 60±1%Hz (battery mode) | |||||
| Waveform | Pure Sine Wave THD | |||||
| Crest factor | 3:1 | |||||
| Harmonic distortion | ≤ 2% (linear load); ≤ 5% (non-linear load) | |||||
| Transfer time | Mains mode to battery mode: 0ms | |||||
| Inverter mode to bypass mode: 4ms (typical) | ||||||
| Overload capability | 105% ~ 125%≥60s | |||||
| 125% ~ 150%≥30s | ||||||
| The recover point is 70% | ||||||
| EFFICIENCY | ||||||
| AC mode | ≥ 92% | |||||
| Battery mode | ≥ 90% | |||||
| ECO mode | ≥ 95% | |||||
| BATTERY | ||||||
| DC voltage | 24V | 36V | 48V | 72V | 72V | 96V |
| Inbuilt battery | 2×7Ah | External | 4×7Ah | External | 6×7Ah | External |
| Back up time | 50% loaded≥ 8minutes;100%≥ loaded 3minutes(standard) | |||||
| Recharge time | Charger to 90% battery capacity in 5 hours(standard)Dependent on the capacity of external batteries (long backup time) | |||||
| ALARMS | ||||||
| Utility failure | 4s per beep | |||||
| Low battery | 1st per beep | |||||
| Overload | 1st per beep | |||||
| UPS fault | Long beep | |||||
| COMMUNICATIONS | ||||||
| RS232 RS485 (optional) | Supports Windows® 98 / 2000 / 2003 / XP / Vista / 2008 / Windows® 7 / 8 / 10 | |||||
| Dry contact (optional) | Power manager and web browser | |||||
| OTHERS | ||||||
| Operating temperature | 0 ~ 40℃ | |||||
| Relative Humidity | 0 ~ 90% RH(non-condensing) | |||||
| Noise level |
| |||||
| Dimensions (D×W×H) mm | 282 X 145 X 220 | 282 X 145 X 220 | 397 X 145 X 220 | 397 X 145 X 220 | 421 X 190 X 318 | 397 X 145 X 220 |
| Net weight (kg) | 9.8 | 4.1 | 17 | 6.8 | 27.6 | 7.4 |