Banatton Understanding Online Three-Phase and Pure Sine Wave UPS Systems
Description
Brand: Banatton
Place of origin: China
Type: online UPS
Model Number: BNT9300-M 20~300KVA
Phase: Three Phase
Waveform: Pure sine wave
Transfer time: 0ms
Power factor: 0.9
Capacity: 20KVA-300KVA
Protection: short-circuit, over voltages, reverse connection protection
OEM/ODM: Yes
Supply Ability: 5000 Piece/Pieces per Month
Packaging: Carton or wooden box package or as you requested
Features
Title: "Choosing the Right UPS for Your Data Center: Understanding Online, Three-Phase, and Pure Sine Wave UPS Systems"
In today's digital age, data centers are the backbone of businesses, storing critical information and ensuring seamless operations. To protect these valuable assets, uninterruptible power supply (UPS) systems are critical. However, with the countless options available, determining the best UPS for your data center can be challenging. In this blog, we’ll dive into the key differences between online UPS, three-phase UPS, and pure sine wave UPS systems to help you make an informed decision.
Online UPS: Also known as a double conversion UPS, online UPS systems provide the highest level of protection against power disturbances. They continuously convert AC power to DC power and back again, ensuring seamless transition during power outages. This makes them ideal for data centers, where even the slightest power fluctuations can cause data corruption or hardware damage.
Three-Phase UPS: Designed for large data centers and industrial applications, three-phase UPS systems are capable of handling higher power loads and provide redundancy to ensure uninterrupted operations. They are critical for facilities with high-density server racks and equipment requiring three-phase power.
Pure Sine Wave UPS: Pure Sine Wave UPS systems provide clean, stable power output that replicates mains power and ensures compatibility with sensitive electronic equipment. They are particularly beneficial for data centers that house servers, storage and networking equipment that are susceptible to damage from harmonic distortion and voltage fluctuations.
When selecting a UPS for your data center, it's important to consider specific power requirements, load capacity, and the importance of protected equipment. Additionally, factors such as scalability, maintenance requirements and energy efficiency should be considered to ensure the solution is reliable and cost-effective.
At UPS 230V, we offer a full range of UPS systems, customized to meet the diverse needs of data centers. Our team of experts can help you choose the most suitable UPS solution and provide ongoing support to ensure the continued operation of your critical infrastructure.
In summary, investing in the right UPS system is critical to safeguarding the integrity and reliability of your data center. By understanding the differences between online UPS, three-phase UPS, and pure sine wave UPS systems, you can make informed decisions that match your facility's unique requirements.
Little Hint
1. In the warranty period the machine has a problem, please contact the sales staff, we will be responsible for customer service.
2. Exceed the warranty period, improper operation and man-made damage, we will still give help and support, we will provide spare parts at a cost price.
3. According to the customer's needs, we can provide unconventional, but the cost may be slightly higher than the traditional machine.
Applications
Data processing center, The host system, Computer servers, Medical, Traffic, Electricity, IT, Industrial and other industries.
Factory Production Line
Packaging
MODEL | BNT990-M | BNT9150/180-M | BNT9300-M | |
Rated Capacity | Cabinet Capacity | 20-90kVA / 20-90kW | 25-150kVA / 25-150kW 30-180kVA / 30-180kW | 30-300kVA / 30-300kW |
One Ppwer Module Capacity | 20kVA /20kW, 25kVA /25kW,30kVA /30kW | |||
MAX. Power Module NO. | 3 | 5/6 | 10 | |
INPUT | ||||
Main Input | Nominal Voltage(Vac) | 380/400/415 | ||
Voltage Range(Vac) | 138~485Vac;305~485Vac load,138~305Vac load | |||
Phase | 3-phase in / 3-phase out | |||
Nominal Frequency(Hz) | 40-70 | |||
Power Factor | ≥0.99 | |||
Harmonic Distortion (THDi) | ≤3% (100% load) | |||
Bypass Input | Nominal Voltage(Vac) | 380/400/415 | ||
Voltage Range(Vac) | 220 Vac:25%(+10%,+15%,+20%) | |||
230 Vac:20%(+10%,+15%) | ||||
240 Vac:15%(+10%);-45%(-10%,-20%,-30%) | ||||
Phase | 3-phase in / 3-phase out | |||
Power Walking In | YES | |||
Bypass Back Irrigation | YES | |||
Generator Access | YES | |||
OUTPUT | ||||
Voltage(Vac) | 380/400/415±1% | |||
Power factor | 1 | |||
Frequency(Hz) | AC Mode | ±1%/±2%/±4%/±5%/±10% | ||
Battery Mode | (50/60±0.1%)Hz | |||
Waveform | Pure Sinewave | |||
Admissible Crest Factor | 3:01 | |||
Harmonic Distortion(THDV) | ≤2% (100%Linear Load);≤3% (100%Non-linear Load) | |||
Transfer Time(ms) | 0 | |||
Efficiency(%) | 95.50% | |||
Overload Capability | 1 hour for 110%, 10 mins for 125%,1 min for 150%, 200ms for >150% | |||
BATTERY | ||||
Maximum Charging Current(A) | 18 | |||
Nominal Voltage | ±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc | |||
(30/32/34/36/38/40/42/44/46/48/50 pcs) | ||||
ENVIRONMENT | ||||
Operating Temperature | 0℃~40℃ | |||
Storage Temperature | -25℃~55℃ | |||
Relative Humidity | 0~95% | |||
Altitude | ||||
Noise Level(dB) | ||||
PHYSICAL | ||||
Dimension (D x W x H) mm | UPS Cabinet | 600×850×1350 | 600×850×1350 600×850×1550 | 600×850×2000 |
Module | 440×620×86 | |||
Net Weight(kg) | UPS Cabinet | 140 | 155/170 | 290 |
Module | twenty one |