Banatton UPS Uninterruptible power supply 30KVA 60KVA three 220V for the machine room.
Description
Brand: Banatton
Place of origin: China
Type: online UPS
Model Number: BNT9300-M 20~300KVA
Phase: Three Phase
Waveform: Pure sine wave
Transfer time: 0ms
Power factor: 0.9
Capacity: 20KVA-300KVA
Protection: short-circuit, over voltages, reverse connection protection
OEM/ODM: Yes
Supply Ability: 5000 Piece/Pieces per Month
Packaging: Carton or wooden box package or as you requested
Features
Title: The importance of 60KVA three-phase UPS for uninterruptible power supply
In today's digital age, businesses rely heavily on technology to operate efficiently. From data centers to manufacturing plants, uninterruptible power supplies are critical to keeping operations running smoothly. This is where the 60KVA three-phase UPS (uninterruptible power supply) comes into play.
The 60KVA UPS is designed to provide backup power to critical systems during power outages or surges. The three-phase output ensures balanced and reliable power supply to sensitive equipment, making it ideal for industrial and commercial applications.
One of the key advantages of a 60KVA UPS is its ability to seamlessly transition to battery power in the event of a power failure, ensuring continuous operation without any interruption. This is especially important for businesses that cannot afford downtime, such as data centers, hospitals, and financial institutions.
Additionally, 60KVA UPS offers scalability and flexibility, allowing businesses to expand their backup power capacity as demand grows. This makes it a cost-effective solution for long-term power protection.
In addition to providing backup power, a 60KVA UPS also helps regulate voltage and frequency, protecting sensitive equipment from damage caused by power surges or fluctuations. This is critical to maintaining the reliability and longevity of expensive mechanical and electronic equipment.
When selecting a 60KVA UPS, it is important to consider factors such as efficiency, reliability and ease of maintenance. Investing in a high-quality UPS from a reputable manufacturer can give you peace of mind and ensure critical systems remain operational during unexpected power events.
In summary, a 60KVA three-phase UPS is an important part of any business’s power infrastructure. Its ability to provide uninterrupted power, regulate voltage and protect sensitive equipment makes it a valuable investment for businesses across a variety of industries. By ensuring continued operations, businesses can minimize the risk of downtime and maintain productivity, ultimately increasing customer satisfaction and business success.
Little Hint
1. In the warranty period the machine has a problem, please contact the sales staff, we will be responsible for customer service.
2. Exceed the warranty period, improper operation and man-made damage, we will still give help and support, we will provide spare parts at a cost price.
3. According to the customer's needs, we can provide unconventional, but the cost may be slightly higher than the traditional machine.
Applications
Data processing center, The host system, Computer servers, Medical, Traffic, Electricity, IT, Industrial and other industries.
Factory Production Line
Packaging
MODEL | BNT990-M | BNT9150/180-M | BNT9300-M | |
Rated Capacity | Cabinet Capacity | 20-90kVA / 20-90kW | 25-150kVA / 25-150kW 30-180kVA / 30-180kW | 30-300kVA / 30-300kW |
One Ppwer Module Capacity | 20kVA /20kW, 25kVA /25kW,30kVA /30kW | |||
MAX. Power Module NO. | 3 | 5/6 | 10 | |
INPUT | ||||
Main Input | Nominal Voltage(Vac) | 380/400/415 | ||
Voltage Range(Vac) | 138~485Vac;305~485Vac load,138~305Vac load | |||
Phase | 3-phase in / 3-phase out | |||
Nominal Frequency(Hz) | 40-70 | |||
Power Factor | ≥0.99 | |||
Harmonic Distortion (THDi) | ≤3% (100% load) | |||
Bypass Input | Nominal Voltage(Vac) | 380/400/415 | ||
Voltage Range(Vac) | 220 Vac:25%(+10%,+15%,+20%) | |||
230 Vac:20%(+10%,+15%) | ||||
240 Vac:15%(+10%);-45%(-10%,-20%,-30%) | ||||
Phase | 3-phase in / 3-phase out | |||
Power Walking In | YES | |||
Bypass Back Irrigation | YES | |||
Generator Access | YES | |||
OUTPUT | ||||
Voltage(Vac) | 380/400/415±1% | |||
Power factor | 1 | |||
Frequency(Hz) | AC Mode | ±1%/±2%/±4%/±5%/±10% | ||
Battery Mode | (50/60±0.1%)Hz | |||
Waveform | Pure Sinewave | |||
Admissible Crest Factor | 3:01 | |||
Harmonic Distortion(THDV) | ≤2% (100%Linear Load);≤3% (100%Non-linear Load) | |||
Transfer Time(ms) | 0 | |||
Efficiency(%) | 95.50% | |||
Overload Capability | 1 hour for 110%, 10 mins for 125%,1 min for 150%, 200ms for >150% | |||
BATTERY | ||||
Maximum Charging Current(A) | 18 | |||
Nominal Voltage | ±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc | |||
(30/32/34/36/38/40/42/44/46/48/50 pcs) | ||||
ENVIRONMENT | ||||
Operating Temperature | 0℃~40℃ | |||
Storage Temperature | -25℃~55℃ | |||
Relative Humidity | 0~95% | |||
Altitude | ||||
Noise Level(dB) | ||||
PHYSICAL | ||||
Dimension (D x W x H) mm | UPS Cabinet | 600×850×1350 | 600×850×1350 600×850×1550 | 600×850×2000 |
Module | 440×620×86 | |||
Net Weight(kg) | UPS Cabinet | 140 | 155/170 | 290 |
Module | twenty one |